Screw compressor installation guide




















The relative humidity of the air should be low, the dust is small, the air is clean and well ventilated;. The compressor air outlet line should preferably have a check valve. Ball valves or automatic drain valves should be installed at the end of the main line to facilitate condensation discharge.

If you need to reduce or enlarge the pipeline, you must use a reducer. Otherwise, there will be mixed flow at the joint, which will cause large pressure loss and affect the service life of the pipeline. Such a gas storage tank can filter part of the condensed water, and the gas storage tank also has the function of lowering the temperature of the compressed air.

Air at a lower temperature and less water re-enters the dryer, reducing the load on the dryer or filter. The foundation plane should be leveled before installation to avoid noise caused by vibration of the compressor.

However, the ground on which it is placed must be flat and the ground should not be soft soil. The bottom of the compressor is preferably covered with a mm cushion or shock pad to prevent vibration and noise. Do not place the compressor near high-temperature equipment to avoid the compressor from inhaling high temperature and the exhaust gas temperature is too high and affect the normal operation of the unit. The capacity of the pumping and exhausting equipment must be greater than the exhaust air volume of the compressor cooling fan.

Moreover, the position of the air outlet should be suitable for the hot exhaust outlet of the compressor. As a professional air compressor installation company with more than 40 years of experience, Lewis Systems can help make sure your system is set up for success. Feel free to contact us at Charlotte, NC. Lynchburg, VA. Greensboro, NC. Rocky Mount, NC.

Get promotions, news, and helpful tips. Subscribe View Newsletter Archives ». Search Search for:. Home About Blog Contact Us. Follow Us On. Contact Us Today. Posted April 21, Ventilation Indoor compressors need to be in a well-ventilated space. Clearance Around Equipment All air compressor equipment should have a minimum of three feet of clearance on each side. Electrical Access Whether indoors or outdoors, your compressor will need access to electricity. Air Compressor Maintenance Plan The most effective way to avoid breakdowns in the future is to have a preventive maintenance plan in place when the machine is installed.